Add to Favorites | Chinese
Position:home>News>
American FLUKE is tasted newly roll out - the spot safeguards technical personne
From;    Author:Stand originally

For design of electric technology personnel, you Fulu overcomes a company to make.

What safeguard technical personnel to use for the spot is compact model appearance of true virtual value. Fluke 115C is to be used at extensive electric the solution that checks application with the electron.

Still have Fluke 114 additionally electric the electrician that measures the avometer of avometer, Fluke 116C HVAC that takes temperature and microamper to measure a function and belt to be not contact voltage to measure a function uses Fluke 117C avometer.

Fluke 115C spot maintains technical staff with avometer

Fluke 115C

    AutoVolt: Automatic choice communicates / although smooth illume of back of LED of white of volts d.c. is in the position with weaker light also resistor of can effective reading and successional the least value / maximum / average measures a function, safety of CAT III 600 V of circumstance of record signal wave motion class

    Safety standard accordance

    The protection of all inputs accords with CE, IEN61010-1 CAT III 600V. Pass UL, CSA, TÜV and VDE attestation.

    The surge of 600v of the biggest voltage between terminal of technical standards random and ground protects 6 KV peak value, according to IEC 61010-1 600 V CAT III; Contaminative grade 2 shows a number: 6000 words, histogram of second of newer rate 4/ 33 paragraphs, c of ° of "-10 of temperature of job of second of newer rate 32/ stores to C of 50 ° C of ° of temperature "-40 comes 9 V of type of cell of C of 60 ° is alkalescent batteries, life of battery of NEDA 1604A/ IEC 6LR61 400 hours (typical cost) , illume of the light that do not have a back

    Accuracy technology standards sheds MV span continuously: 600.0 MV resolution: 0.1 MV accuracy: ± ([% reading] [word] ) : Span of V of 2.0% 3 dc / resolution: Span of 6.000 V / 0.001 V / resolution: Span of 60.00 V / 0.01 V / resolution: Automatic voltage of 600.00 V / 0.1 V chooses span: 600.0 V resolution: 0.1 V accuracy: 2.0 % 3 (dc, 45 Hz comes 500 Hz) ; 4.0 % 3 (500 Hz comes 1 KHz) millivolt communicates span of 1 true virtual value: 600.0 MV resolution: 0.1 MV accuracy: 1.0 % 3 (dc, 45 Hz comes 500 Hz) ; 2.0 % 3 (500 Hz comes 1 KHz) alternating voltage span of 1 true virtual value / resolution: Span of 6.000 V / 0.001 V / resolution: Span of 60.00 V / 0.01 V / resolution: Accuracy of 600.0 V / 0.1 V: 1.0 % 3 (dc, 45 Hz comes 500 Hz) ; 2.0 % 3 (500 Hz comes 1 KHz) successional span: 600ΩResolution: 1ΩAccuracy: Sound warning apparatus<20ΩPut through when, >250ΩShut when; Detect S of 500 μ or longer the open a way when or short circuit. Resistor span / resolution: 600Ω/ 0.1ΩSpan / resolution: 6.000 KΩ/ 0.001 KΩSpan / resolution: 60.00 KΩ/ 0.01 KΩSpan / resolution: 600.0 KΩ/ 0.1 KΩSpan / resolution: 6.000 MΩ/ 0.001 MΩAccuracy: Span of 0.9 % 1 / resolution: 40.00 MΩ/ 0.01 MΩAccuracy 1.5 % 2
    Previous12 Next

About us | Legal Notices | Sitemap | links | Partner